An Implant Category of Its Own

The only conforming, patient specific expandable implant - OptiMesh® accommodates a patient’s unique requirements and provides unparalleled versatility to support a surgeon’s procedural preference.

Conform and Expand™ Technology

Conform and Expand technology is designed to provide a custom anatomical fit for lumbar fusion surgical patients. OptiMesh’s powerful distraction forces and conformance to the endplates provide strength and stability to restore disc height, achieve alignment goals, and promote a robust fusion.1

OptiMesh Implant

The only conforming, patient specific expandable implant.

Conform and Expand Technology

Conform and Expand™ Technology

Starting one of the smallest insertion profiles, expands to one of the largest implant footprints available, up to 29mm wide and 34mm long.

Dynamically confirms to a patient's unique endplate morphology, providing a custom anatomical fit every time. 

Powerful Distraction

Powerful Distraction

Generates significant distraction forces to restore disc height and achieve alignment goals.

Strength through Granular Mechanics

Strength through Granular Mechanics

Compaction of the proprietary fill material creates a robust platform for restoration of disc height and alignment, and promotes a robust biological environment for fusion.

Greatest Expansion Range

Greatest Expansion Range*

20mm of continuous expansion. Multiplanar expansion to the size of an ALIF implant.

Highest Pourous Enabling Fusion

Highest Pourous Enabling Fusion

1500-micron pore size facilitates graft containment while allowing for bony through growth.1

Granular bone graft creates interconnected, interstitial spaces throughout the graft pack, providing an osteoconductive scaffold to support fusion.

*Data on file.

OptiMesh Instrumentation

Streamlined access to the disc space, and proprietary preparation instrumentation to provide a thorough, reproducible discectomy through the smallest working channel. 

Neuromonitoring Probe

Neuromonitoring Probe gains reproducible access to the disc space through Kambin's triangle. 

Access Portal

Access Portal placement allows for fewer passes by the nerve root to help decrease risk of neural injury.

Drill

Drill creates initial channel.

Shaver

Expanding rotating shaver to widen discectomy and remove cartilage from vertebral body endplates.

Articulating Curettes

Articulating Curettes broaden the cavity further and decorticate he vertebral body endplates. 

Brush

Tissue is removed using Tissue Extractor Brushes.

Verify

The Verify™ device is used to visualize the quality of the discectomy and endplate preparation prior to implant placement. 

OptiMesh®

OptiMesh® is deployed into the disc space through the Access Portal, expanding and conforming in-situ to vertebral endplates. 

OptiMesh

Unparalleled Versatility

Open

TLIF/PLIF

MIS

TLIF

Ultra-MIS

OptiLIF®

Ultra-MIS

OptiLIF® Endo

A single implant may be used for multiple lumbar fusion approaches accommodating patient specific needs. No matter your approach to lumbar fusion, OptiMesh provides a best in class expandable interbody solution from Open, MIS TLIF, ultra-MIS (OptiLIF), to endoscopic fusion (OptiLIF Endo) applications.

Unmatched Clinical Experience

The SCOUT IDE Study

Unique in design and in published data, OptiMesh holds the highest achievement in clinical validation with an IDE De Novo level grant. Spineology Clinical Outcomes Trial (SCOUT Study): IDE trial of a novel, conformable device placed in the disc space through a small portal and filled with bone graft in-situ. At 24 months:

  • 92% patients rated satisfaction as excellent/good
  • Mean ODI improved 32.0 ± 18.5
  • 99% (95/96) fusion

0%

98% fusion at 12 months post-op, evaluated by two independent radiologists.

0%

85% of patients experienced a clinically meaningful reduction in back pain at 3 months.

0%

75% of patients experienced a clinically meaningful improvement in back function at 3 months.

0%

92% of patients rated their satisfaction "excellent" or "good" at 6 months.

There were no device-related serious adverse events.

Chi J, Nunley P, et al. Two-Year Outcomes From a Prospective Multicenter Investigation Device Trial of a Novel Conformal Mesh Interbody Fusion Device. Int J Spine Surg. 2021 Dec; 15(6): 1103-1114.

Whitepapers@4x

Unique in Data

20 Clinical Publications

> 50,000 implants

Additionally, 20+ years of clinical experience, 20 clinical publications, and > 50,000 devices implanted set OptiMesh alone in the interbody fusion space.

Scroll to Top